Conductor
Insulation
Sheath
Min Operating Temperature
Max Operating Temperature
Min Bending Radius
Core Colours
Sheath Colours
Current Carrying Capacity
Manufactured to BS EN 50525-2-11:2011 Clause 4.1, Table B.1
Flexible annealed copper conductor, PVC insulated, PVC sheathed light duty cords 300/300V parallel twin, circular twin, 3 core and 4 core
Light duty cords/flexibles are used where the risk of mechanical damage and mechanical stresses is low, i.e. under external influences to be expected in the normal use of light, hand-held appliances and light portable equipment in domestic premises, offices and shops.
Examples of appliances that need light duty cables include domestic hair dryers and hair styling appliances, radio sets, table and standard lamps and small desktop machines.
Reference Number | Harmonisation Code | Nominal Cross Sectional Area of Conductor (mm2) | Nominal Stranding of Conductor (mm) | Nominal Radial Thickness of insulation (mm) | Nominal Radial Thickness of sheath (mm) | Overall Diameter Lower Limit (mm) | Overall Diameter Upper Limit (mm) | Approximate Weight (kg/km) |
---|---|---|---|---|---|---|---|---|
2182Y0.5 | H03VV-F | 0.5 | 16/0.2 | 0.5 | 0.6 | 4.6 | 5.9 | 41 |
2182Y0.75 | H03VV-F | 0.75 | 24/0.2 | 0.5 | 0.6 | 4.9 | 6.3 | 50 |
2183Y0.5 | H03VV-F | 0.5 | 16/0.2 | 0.5 | 0.6 | 4.9 | 6.3 | 48 |
2183Y0.75 | H03VV-F | 0.75 | 24/0.2 | 0.5 | 0.6 | 5.2 | 6.7 | 57 |
2184Y0.5 | H03VV-F | 0.5 | 16/0.2 | 0.5 | 0.6 | 5.4 | 6.9 | 53 |
2184Y0.75 | H03VV-F | 0.75 | 24/0.2 | 0.5 | 0.6 | 5.7 | 7.3 | 63 |